Improvement of Plasma Performance with Lithium Wall Conditioning in Aditya Tokamak

Lithiumization of the vacuum vessel wall of the Aditya tokamak using a lithium rod exposed to glow discharge cleaning plasma has been done to understand its effect on plasma performance. After the Li-coating, an increment of ~100 eV in plasma electron temperature has been observed in most of the dis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Plasma science & technology 2013-02, Vol.15 (2), p.123-128
Hauptverfasser: Chowdhuri, M. B., Manchanda, R., Ghosh, J., Bhatt, S. B., Kumar, Ajai, Das, B. K., Jadeja, K. A., Raijada, P. A., Kumar, Manoj, Banerjee, S., Ramaiya, Nilam, Mali, Aniruddh, Patel, Ketan M., Kumar, Vinay, Vasu, P., Bhattacharyay, R., Tanna, R. L., Joisa, Y. Shankara, Atrey, P. K., Rao, C. V. S., Reddy, D. Chenna, Chattopadhyay, P. K., Jha, R., Saxena, Y. C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Lithiumization of the vacuum vessel wall of the Aditya tokamak using a lithium rod exposed to glow discharge cleaning plasma has been done to understand its effect on plasma performance. After the Li-coating, an increment of ~100 eV in plasma electron temperature has been observed in most of the discharges compared to discharges without Li coating, and the shot reproducibility is considerably improved. Detailed studies of impurity behaviour and hydrogen recycling are made in the Li coated discharges by observing spectral lines of hydrogen, carbon, and oxygen in the visible region using optical fiber, an interference filter, and PMT based systems. A large reduction in O I signal (up to ~40% to 50%) and a 20% to 30% decrease of Ha signal indicate significant reduction of wall recycling. Furthermore, VUV emissions from O V and Fe XV monitored by a grazing incidence monochromator also show the reduction. Lower Fe XV emission indicates the declined impurity penetration to the core plasma in the Li coated discharges. Significant increase of the particle and energy confinement times and the reduction of Zeff of the plasma certainly indicate the improved plasma parameters in the Aditya tokamak after lithium wall conditioning.
ISSN:1009-0630
DOI:10.1088/1009-0630/15/2/09