A Systematic Review and Meta-analysis of Endovascular Popliteal Aneurysm Repair Using the Hemobahn/Viabahn Stent-Graft
Purpose: To perform an evidence synthesis study to assess outcomes of endovascular repair of popliteal artery aneurysms (PAAs) using the Hemobahn or Viabahn stent-graft. Methods: A systematic literature review was conducted conforming to established standards to identify articles published between 1...
Gespeichert in:
Veröffentlicht in: | Journal of endovascular therapy 2015-06, Vol.22 (3), p.330-337 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose: To perform an evidence synthesis study to assess outcomes of endovascular repair of popliteal artery aneurysms (PAAs) using the Hemobahn or Viabahn stent-graft. Methods: A systematic literature review was conducted conforming to established standards to identify articles published between 1996 (the date of introduction of the Hemobahn stent-graft) and 2013 reporting stent-graft repair of PAAs in at least 10 patients. The data were pooled for Kaplan-Meier analysis of primary and secondary patency rates [presented with 95% confidence intervals (CIs)] as the primary outcomes. Random effects meta-analysis was performed for secondary outcomes that included rates of reintervention, endoleak, stent-graft fracture, and limb salvage. Results: Fourteen studies reported outcomes for 514 PAAs. There was considerable heterogeneity in reporting standards among studies. Pooled primary and secondary patency rates were 69.4% (95% CI 63.3% to 76.2%) and 77.4% (95% CI 70.1% to 85.3%), respectively, at 5 years. Five studies (including only one randomized controlled trial) compared surgical to endovascular repair; no difference was found in primary patency on evidence synthesis (hazard ratio 1.30, 95% CI 0.79 to 12.14, p=0.189). Conclusion: Stent-graft repair provides a feasible treatment option for anatomically suitable PAAs. Further studies are required to optimize both patient selection and follow-up protocols. |
---|---|
ISSN: | 1526-6028 1545-1550 |
DOI: | 10.1177/1526602815579252 |