Evaluation of different mathematical models for diffusion-weighted imaging of normal prostate and prostate cancer using high b-values: A repeatability study
Purpose To evaluate monoexponential, stretched exponential, kurtosis, and biexponential models for diffusion‐weighted imaging (DWI) of normal prostate and prostate cancer (PCa), using b‐values up to 2000 s/mm2, in terms of fitting quality and repeatability. Methods Eight healthy volunteers and 16 PC...
Gespeichert in:
Veröffentlicht in: | Magnetic resonance in medicine 2015-05, Vol.73 (5), p.1988-1998 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
To evaluate monoexponential, stretched exponential, kurtosis, and biexponential models for diffusion‐weighted imaging (DWI) of normal prostate and prostate cancer (PCa), using b‐values up to 2000 s/mm2, in terms of fitting quality and repeatability.
Methods
Eight healthy volunteers and 16 PCa patients underwent a total of four repeated 3T DWI examinations using 16 and 12 b‐values, respectively. The highest b‐value was 2000 s/mm2. The normalized mean signal intensities of regions of interest, placed in normal tissue and PCa using anatomical images and prostatectomy sections, were fitted using the four models. The fitting quality was evaluated using Akaike information criteria and F‐ratio. Repeatability of the fitted parameters was evaluated using intraclass correlation coefficient ICC(3,1).
Results
The biexponential model provided the best fit to normal prostate and PCa DWI data. The parameters of the monoexponential, kurtosis, and stretched exponential (with the exception of the α parameter) models had higher ICC(3,1) values compared with the biexponential model. The kurtosis model provided a better fit to DWI data of normal prostate and PCa than the monoexponential model, whereas these models had comparable reliability and repeatability based on ICC(3,1) values.
Conclusion
Considering the model fit and repeatability, the kurtosis model seems to be the preferred model for characterization of normal prostate and PCa DWI using b‐values up to 2000 s/mm2. Magn Reson Med 73:1988–1998, 2015. © 2014 Wiley Periodicals, Inc. |
---|---|
ISSN: | 0740-3194 1522-2594 |
DOI: | 10.1002/mrm.25323 |