Renal perfusion evaluation by alternating current biosusceptometry of magnetic nanoparticles
Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200μL of magnetic nanoparticles with a concentration of 23mg/mL in the femoral vein and the measurement of the signal above...
Gespeichert in:
Veröffentlicht in: | Journal of magnetism and magnetic materials 2015-04, Vol.380, p.2-6 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Alternating current susceptometry, a simple and affordable technique, was employed to study the sensitivity of this approach to assess rat kidney perfusion by the injection of 200μL of magnetic nanoparticles with a concentration of 23mg/mL in the femoral vein and the measurement of the signal above the kidney. The instrument was able to detect the signal and the transit time of the first and second pass were measured in five animals with average values of 13.6±4.3s and 20.6±7.1s.
•Rat kidney transit time of magnetic nanoparticles was measured with biosusceptometry.•AC biosusceptometry has sensitivity to measure magnetic nanoparticles in rat kidney.•AC susceptometry has good potential for in vivo studies of magnetic nanoparticles. |
---|---|
ISSN: | 0304-8853 |
DOI: | 10.1016/j.jmmm.2014.09.073 |