Comparative stability of the bioresorbable ferric crosslinked hyaluronic acid adhesion prevention solutions

The Intergel® ferric crosslinked hyaluronate (FeHA) adhesion prevention solution (APS) (FDA) is associated with serious post‐operative complications (Henley, http://www.lawyersandsettlements.com/features/gynecare‐intergel/intergel‐timeline.html, 2007; FDA, 2003; Roman et al., Fertil Steril 2005, 83...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomedical materials research. Part B, Applied biomaterials Applied biomaterials, 2013-08, Vol.101B (6), p.1006-1013
Hauptverfasser: Luu, Hoan-My Do, Chen, Angela, Isayeva, Irada S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The Intergel® ferric crosslinked hyaluronate (FeHA) adhesion prevention solution (APS) (FDA) is associated with serious post‐operative complications (Henley, http://www.lawyersandsettlements.com/features/gynecare‐intergel/intergel‐timeline.html, 2007; FDA, 2003; Roman et al., Fertil Steril 2005, 83 Suppl 1:1113–1118; Tang et al., Ann Surg 2006;243(4):449–455; Wiseman, Fertil Steril 2006;86(3):771; Wiseman, Fertil Steril 2006;85(4):e7). This prompted us to examine the in situ stability of crosslinked HA materials to hyaluronidase lyase degradation. Variables such as ferric ionic crosslink density, HA concentration, gel geometry, and molecular weight (MW) of HA polymer were studied. Various formulations of the crosslinked “in house” [Isayeva et al., J Biomed Mater Res: Part B – Appl Biomater 2010, 95B (1):9–18] FeHA (0.5%, w/v; 30, 50, 90% crosslinked), the Intergel® FeHA (0.5%, w/v; 90%), and the non‐crosslinked HA (0.05–0.5%, w/v) were degraded at a fixed activity of hyaluronidase lyase from Streptomyces hyalurolyticus (Hyase) at 37°C over time according to the method [Payan et al., J Chrom B: Biomed Sci Appl 1991;566(1):9–18]. Under our conditions, the data show that the crosslink density affects degradation the most, followed by HA concentration and then gel geometry. We found that MW has no effect. Our results are one possible explanation of the observations that the Intergel® FeHA APS (0.5%, w/v; 90%) material persisted an order of magnitude longer than expected [t1/2 = 500 hrs vs. t1/2 = 50 hrs (FDA; Johns et al., Fertil Steril 1997;68(1):37–42)]. These data also demonstrate the sensitivity of the in vitro hyaluronidase assay to predict the in situ stability of crosslinked HA medical products as previously reported [Sall et al., Polym Degrad Stabil 2007;92(5):915–919]. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.
ISSN:1552-4973
1552-4981