Spinal sealant system provides better intraoperative watertight closure than standard of care during spinal surgery: a prospective, multicenter, randomized controlled study

Prospective, 3:1 randomized, single-blind, multicenter investigational study. To assess the safety and efficacy of a low-swell spinal sealant when used as an adjunct to sutured dural repair compared with standard of care methods to obtain watertight dural closure in subjects undergoing spinal surger...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Spine (Philadelphia, Pa. 1976) Pa. 1976), 2015-04, Vol.40 (8), p.505-513
Hauptverfasser: Wright, Neill M, Park, Jon, Tew, John M, Kim, Kee D, Shaffrey, Mark E, Cheng, Joseph, Choudhri, Haroon, Krishnaney, Ajit A, Graham, R Scott, Mendel, Ehud, Simmons, Nathan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Prospective, 3:1 randomized, single-blind, multicenter investigational study. To assess the safety and efficacy of a low-swell spinal sealant when used as an adjunct to sutured dural repair compared with standard of care methods to obtain watertight dural closure in subjects undergoing spinal surgery. Watertight dural closure is paramount in spinal surgery to avoid complications of cerebrospinal fluid leak. Prior reports have proven the efficacy of a synthetic, absorbable polyethylene glycol (PEG) hydrogel sealant in spinal surgery compared with standard of care. Given the potential concerns of swelling in spinal applications, the hydrogel was modified to a low-swell formulation. The primary endpoint was success rate in obtaining intraoperative watertight dural closure in subjects receiving PEG hydrogel sealant versus a control group of subjects receiving any standard method designed to provide intraoperative watertight closure. Subjects were evaluated at discharge and at 30 and 90 days postprocedure for cerebrospinal fluid leaks, surgical site infections, and adverse events. Between May 2007 and May 2009, 98 subjects (74 PEG hydrogel spinal sealant, 24 control) were randomized at 14 clinical sites in the United States. Patients treated with the PEG hydrogel spinal sealant had a significantly higher rate of watertight closure than the control (98.6% vs. 79.2%, P = 0.003). No statistical differences were seen in postoperative cerebrospinal fluid, infection, and wound healing. No neurological deficits were seen attributable to the sealant. The low-swell PEG hydrogel spinal sealant evaluated in this study has been proven safe and effective for providing watertight closure when used as an adjunct to sutured closure of intentional durotomies during spinal surgery. PEG hydrogel sealants have again proved superior to other standard of care technologies for safe, efficacious dural closure. 2.
ISSN:0362-2436
1528-1159
DOI:10.1097/BRS.0000000000000810