Analysis of Lead in SnAg Based Solders Using X-Ray Fluorescence
This paper reports the results of ED-XRF method for the determination of low-level contaminated solders. The method was calibrated for the analysis of part-per-million (ppm) levels of Pb and major levels of other elements. In this work, two types of Sn-Ag based solder alloys are used; the ternary Sn...
Gespeichert in:
Veröffentlicht in: | Materials science forum 2013-03, Vol.752, p.37-41 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper reports the results of ED-XRF method for the determination of low-level contaminated solders. The method was calibrated for the analysis of part-per-million (ppm) levels of Pb and major levels of other elements. In this work, two types of Sn-Ag based solder alloys are used; the ternary Sn-3.0wt%Ag-0.5wt%Cu (SAC305) and the 6-part Sn-3.5wt%Ag-3.2wt%Bi-1.6wt%Sb-0.5wt%Cu-0.15wt%Ni were examined. Empirical calibration and fundamental parameter calibration were used to analyze samples. The results of this study demonstrate the differences between the applied calibration methods for detection of Pb. Screening analysis of bulk samples from variant production lines were also discussed. |
---|---|
ISSN: | 0255-5476 1662-9752 1662-9752 |
DOI: | 10.4028/www.scientific.net/MSF.752.37 |