In situ optical studies of methane and simulated biogas oxidation on high temperature solid oxide fuel cell anodes

Novel integration of in situ near infrared (NIR) thermal imaging, vibrational Raman spectroscopy, and Fourier-transform infrared emission spectroscopy (FTIRES) coupled with traditional electrochemical measurements has been used to probe chemical and thermal properties of Ni-based, solid oxide fuel c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physical chemistry chemical physics : PCCP 2014-01, Vol.16 (1), p.227-236
Hauptverfasser: Kirtley, John D, Steinhurst, Daniel A, Owrutsky, Jeffery C, Pomfret, Michael B, Walker, Robert A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Novel integration of in situ near infrared (NIR) thermal imaging, vibrational Raman spectroscopy, and Fourier-transform infrared emission spectroscopy (FTIRES) coupled with traditional electrochemical measurements has been used to probe chemical and thermal properties of Ni-based, solid oxide fuel cell (SOFC) anodes operating with methane and simulated biogas fuel mixtures at 800 °C. Together, these three non-invasive optical techniques provide direct insight into the surface chemistry associated with device performance as a function of cell polarization. Specifically, data from these complementary methods measure with high spatial and temporal resolution thermal gradients and changes in material and gas phase composition in operando. NIR thermal images show that SOFC anodes operating with biogas undergo significant cooling (ΔT = -13 °C) relative to the same anodes operating with methane fuel (ΔT = -3 °C). This result is general regardless of cell polarization. Simultaneous Raman spectroscopic measurements are unable to detect carbon formation on anodes operating with biogas. Carbon deposition is observable during operation with methane as evidenced by a weak vibrational band at 1556 cm(-1). This feature is assigned to highly ordered graphite. In situ FTIRES corroborates these results by identifying relative amounts of CO2 and CO produced during electrochemical removal of anodic carbon previously formed from an incident fuel feed. Taken together, these three optical techniques illustrate the promise that complementary, in situ methods have for identifying electrochemical oxidation mechanisms and carbon-forming pathways in high temperature electrochemical devices.
ISSN:1463-9076
1463-9084