The Performance Analysis of a Hydrocarbon Refrigerant R-600a in a Household Refrigerator / Freezer
The performance of a hydrocarbon refrigerant, R-600a, as an alternative for R-12 has been evaluated in a 215 household auto-defrost refrigerator/freezer. A theoretical analysis was performed with NIST REFPROP, based on the ASHRAE refrigeration cycle and a series of tests with R-600a was conducted ac...
Gespeichert in:
Veröffentlicht in: | Journal of mechanical science and technology 1998-07, Vol.12 (4), p.753-760 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The performance of a hydrocarbon refrigerant, R-600a, as an alternative for R-12 has been evaluated in a 215 household auto-defrost refrigerator/freezer. A theoretical analysis was performed with NIST REFPROP, based on the ASHRAE refrigeration cycle and a series of tests with R-600a was conducted according to the Korea Standard (KS C 9305). All the tests were performed in the climate chamber of which the temperatures and relative humidities were maintained at 30±1°C and 75±5%, respectively. The test results showed that the energy efficiencies and the cooling speeds with R-600a were improved by 1-11% and 3-10%, respectively, compared to R-12.[PUBLICATION ABSTRACT] |
---|---|