On Reliability of (n + 1)-Unit Warm Standby System based on Imperfect Repair Facility and Two Types of Failures
This paper deals with an (n + 1)-unit warm standby system based on imperfect repair facility and two types of failures. These types of failure are hardware and human error failures. Various measures of the system reliability are obtained using the regenerative point technique. Finally a numerical ex...
Gespeichert in:
Veröffentlicht in: | International journal of computer applications 2013-01, Vol.70 (1), p.1-6 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper deals with an (n + 1)-unit warm standby system based on imperfect repair facility and two types of failures. These types of failure are hardware and human error failures. Various measures of the system reliability are obtained using the regenerative point technique. Finally a numerical example is presented to illustrate the theoretical results. |
---|---|
ISSN: | 0975-8887 0975-8887 |
DOI: | 10.5120/11923-7704 |