On Reliability of (n + 1)-Unit Warm Standby System based on Imperfect Repair Facility and Two Types of Failures

This paper deals with an (n + 1)-unit warm standby system based on imperfect repair facility and two types of failures. These types of failure are hardware and human error failures. Various measures of the system reliability are obtained using the regenerative point technique. Finally a numerical ex...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of computer applications 2013-01, Vol.70 (1), p.1-6
Hauptverfasser: W Mahmoud, M A, Attallah, M A, Alharby, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper deals with an (n + 1)-unit warm standby system based on imperfect repair facility and two types of failures. These types of failure are hardware and human error failures. Various measures of the system reliability are obtained using the regenerative point technique. Finally a numerical example is presented to illustrate the theoretical results.
ISSN:0975-8887
0975-8887
DOI:10.5120/11923-7704