Intercomparison of calibration systems for AC shunts up to audio frequencies

An intercomparison of calibration systems for AC shunts up to audio frequencies (10 kHz) between the National Research Council of Canada, Japan Electric Meters Inspection Corporation, and the National Institute of Standards and Technology, is presented. The comparison was implemented with a transfer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 2005-04, Vol.54 (2), p.507-511
Hauptverfasser: So, E., Angelo, D., Tsuchiyama, T., Tadokoro, T., Waltrip, B.C., Nelson, T.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An intercomparison of calibration systems for AC shunts up to audio frequencies (10 kHz) between the National Research Council of Canada, Japan Electric Meters Inspection Corporation, and the National Institute of Standards and Technology, is presented. The comparison was implemented with a transfer standard of 10 A, 0.1 /spl Omega/ calculable AC/DC shunt, designed by Japan Electric Meters Inspection Corporation. The results indicate that there are no significant differences in the overall accuracy of calibration systems for AC shunts at frequencies up to 10 kHz in each laboratory.
ISSN:0018-9456
1557-9662
DOI:10.1109/TIM.2004.843418