Thermographic detection of surface breaking defects using a scanning laser source

Surface breaking defects are detected using a scanning laser source to deposit heat into a sample surface. Any lateral flow of heat is disturbed by such a defect, with a change in thermal spot shape being detected by an infrared camera. An apparent increase in temperature as the laser passes over a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NDT & E international : independent nondestructive testing and evaluation 2011-11, Vol.44 (7), p.589-596
Hauptverfasser: Burrows, S.E., Dixon, S., Pickering, S.G., Li, T., Almond, D.P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Surface breaking defects are detected using a scanning laser source to deposit heat into a sample surface. Any lateral flow of heat is disturbed by such a defect, with a change in thermal spot shape being detected by an infrared camera. An apparent increase in temperature as the laser passes over a defect is due to a localised change in emissivity, allowing defects to be distinguished from surface markings. Defects have been detected in both stainless steel and aluminium. ► Thermography is used for the detection of surface breaking defects. ► A scanning laser source is used to deposit heat onto a sample surface. ► A change in lateral flow of heat is detected by a thermal imaging camera. ► Apparent rise in temperature as laser passes a defect is due to local change in emissivity.
ISSN:0963-8695
1879-1174
DOI:10.1016/j.ndteint.2011.06.001