Estimating insulin sensitivity from glucose levels only: Use of a non-linear mixed effects approach and maximum a posteriori (MAP) estimation

Abstract Insulin Sensitivity is an important parameter for the management of Diabetes. It can be derived for a particular patient using data derived from some glucose challenge tests using measured glucose and insulin levels at various times. Whilst a useful approach, deriving insulin sensitivities...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Computer methods and programs in biomedicine 2013-02, Vol.109 (2), p.134-143
Hauptverfasser: Yates, James W.T, Watson, Edmund M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Insulin Sensitivity is an important parameter for the management of Diabetes. It can be derived for a particular patient using data derived from some glucose challenge tests using measured glucose and insulin levels at various times. Whilst a useful approach, deriving insulin sensitivities to inform insulin dosing in other settings such as Intensive Care Units can be more challenging – especially as insulin levels have to be assayed in a laboratory, not at the bedside. This paper investigates an approach to measure insulin sensitivity from glucose levels only. Estimates of mean and between individual parameter variances are used to derive conditional estimates of insulin sensitivity. The method is demonstrated to perform reasonably well, with conditional estimates comparing well with estimates derived from insulin data as well.
ISSN:0169-2607
1872-7565
DOI:10.1016/j.cmpb.2011.12.014