Palygorskite–expanded graphite electrodes for catalytic electro-oxidation of phenol
A palygorskite–expanded graphite (EG) electrode was developed for degradation of phenol. Phenol was determined by differential pulse voltammetry (DPV) with this electrode. Compared to carbon paste electrodes and unmodified EG electrodes, the novel electrode appeared to induce catalytic electro-oxida...
Gespeichert in:
Veröffentlicht in: | Applied clay science 2010-06, Vol.49 (1), p.64-68 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A palygorskite–expanded graphite (EG) electrode was developed for degradation of phenol. Phenol was determined by differential pulse voltammetry (DPV) with this electrode. Compared to carbon paste electrodes and unmodified EG electrodes, the novel electrode appeared to induce catalytic electro-oxidation of phenol. The dependence of signals on operating conditions was studied. The modified electrode exhibited a linear response over a wide range of phenol concentrations from 50 to 500
µM, with a detection limit of 4.5
µM (s/n
=
3). Low cost and very simple manufacturing procedure allow for the novel electrodes to be applied as disposable devices for catalytic electro-oxidation of phenol. |
---|---|
ISSN: | 0169-1317 1872-9053 |
DOI: | 10.1016/j.clay.2010.04.003 |