Gas discrimination in an air-conditioned system

In this work, an identification system based on an array of semiconductor tin dioxide gas sensors has been developed. This system has provided a good success rate in the discrimination of carbon dioxide, forane R134a or their mixtures without a sensor dedicated to carbon dioxide. After a characteriz...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on instrumentation and measurement 2000-08, Vol.49 (4), p.809-812
Hauptverfasser: Sarry, F., Lumbreras, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this work, an identification system based on an array of semiconductor tin dioxide gas sensors has been developed. This system has provided a good success rate in the discrimination of carbon dioxide, forane R134a or their mixtures without a sensor dedicated to carbon dioxide. After a characterization of the five-sensor array, pretreatment was tested on the collected data to select the most representative parameters. Then the information contained in the resulting look-up table was analyzed with PCA, but no significant result was observed. Discriminant factorial analysis was then used and has shown a better separation of the different clusters. Next, unknown data were taken to validate the classification. The results show that a reliable system can be designed using nondedicated chemical semiconductor gas sensors.
ISSN:0018-9456
1557-9662
DOI:10.1109/19.863929