The Spatial Effect and Compensation ofCurrent Sensor Differential Gains for Three-Phase Three-Wire Systems
Current sensor errors affect torque control and saliency-tracking position estimation of AC machines. In this paper, a spatial model of current sensor gain deviation is developed and used to determine its effect on general current measurement, verified with experimental data. Three current sensors e...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industry applications 2008-07, Vol.44 (4), p.1181-1189 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Current sensor errors affect torque control and saliency-tracking position estimation of AC machines. In this paper, a spatial model of current sensor gain deviation is developed and used to determine its effect on general current measurement, verified with experimental data. Three current sensors enable a three-phase three-wire system to compensate for current sensor differential gains independent of additional machine saliencies. Simulation and experimental results confirm the current sensor gain-deviation compensation algorithm. |
---|---|
ISSN: | 0093-9994 1939-9367 |
DOI: | 10.1109/TIA.2008.926208 |