Attenuation Effects of Discrete Tone Using Adaptive Feedback Active Noise Control

The attenuation characteristics of a slit resonator that combined the adaptive feedback ANC system at a ventilation aperture of the package for leakage noise is investigated. The discrete tones radiated from an AC axial flow fan are controlled by DSP using Filtered-X Least Mean Square algorithm. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Environment and Engineering 2007, Vol.2(3), pp.470-479
Hauptverfasser: WATANABE, Seiji, YANAGIMOTO, Kensaku, TANIFUJI, Katsuya, SAKAMOTO, Shuichi, TAKAHASHI, Masayuki, ICHIMIYA, Ryoichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The attenuation characteristics of a slit resonator that combined the adaptive feedback ANC system at a ventilation aperture of the package for leakage noise is investigated. The discrete tones radiated from an AC axial flow fan are controlled by DSP using Filtered-X Least Mean Square algorithm. The attenuation is found at the range of: 3dB-14dB with circular slit resonator, 2dB-15dB with elliptic slit resonator. Results of measurement show that the proposed system can achieve TNR(Tone to Noise Ratio) and PR(Prominence Ratio) under threshold effectively.
ISSN:1880-988X
1880-988X
DOI:10.1299/jee.2.470