Non-null testing for standard quadric surfaces with subaperture stitching technique
A new method is proposed for testing standard quadric surfaces with several subapertures based on interferometry. Subapertures arrangement, best-fit sphere calculation and distortion correction about such surfaces are discussed in this paper. In addition, we provide an experimental demonstration by...
Gespeichert in:
Veröffentlicht in: | Optics communications 2015-04, Vol.340, p.159-164 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A new method is proposed for testing standard quadric surfaces with several subapertures based on interferometry. Subapertures arrangement, best-fit sphere calculation and distortion correction about such surfaces are discussed in this paper. In addition, we provide an experimental demonstration by testing a Ø310mm convex hyperboloid mirror. The experimental result shows that the proposed method can accomplish the testing of quadric mirrors without auxiliary compensation effectively. The analysis and proposed methods bring much to the application of non-null aspheric testing. |
---|---|
ISSN: | 0030-4018 1873-0310 |
DOI: | 10.1016/j.optcom.2014.11.075 |