Accuracy of endometrial sampling compared to conventional dilatation and curettage in women with abnormal uterine bleeding

Objectives To compare the diagnostic accuracy of brush endometrial sampling with conventional dilatation and curettage in women with abnormal uterine bleeding. Patients and methods Two hundred and twenty (220) women with abnormal uterine bleeding were included in this comparative study; endometrial...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of gynecology and obstetrics 2015-05, Vol.291 (5), p.1121-1126
Hauptverfasser: Abdelazim, Ibrahim A., Abdelrazak, Khaled M., Elbiaa, Assem A. M., Al-Kadi, Mohamed, Yehia, Amr H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives To compare the diagnostic accuracy of brush endometrial sampling with conventional dilatation and curettage in women with abnormal uterine bleeding. Patients and methods Two hundred and twenty (220) women with abnormal uterine bleeding were included in this comparative study; endometrial sampling was done before cervical dilatation using Tao Bruch followed by conventional dilatation and curettage (D&C). The histopathology report of the Tao Bruch samples was compared with that of the D&C samples and the D&C results were considered as the gold standard. Results 100 % of samples obtained by conventional D&C, while 98.2 % of the samples obtained by Tao Brush were adequate for histopathology examination. In this study; Tao Brush had 100 % sensitivity, 100 % specificity, 100 % predictive values and accuracy for diagnosing endometrial hyperplasia, endometrial carcinoma, proliferative and secretory endometrium, also, it had 86.7 % sensitivity, 100 % specificity, 100 % positive predictive value (PPV) and 99 % negative predictive value (NPV) and accuracy for diagnosing endometritis (no significant difference compared to conventional D&C), while, it had 77.8 % sensitivity, 100 % specificity, 100 % PPV and 99 % NPV and accuracy for diagnosing endometrial polyps (no significant difference compared to conventional D&C) Conclusion Endometrial sampling using endometrial brush cytology (EBC) is safe, accurate, cost-effective outpatient procedure, avoids general anesthesia with high sensitivity and specificity for detection of endometrial hyperplasia and endometrial carcinoma. EBC could be used as complementary diagnostic tool when hysteroscopic biopsies or other blinded procedures for endometrial sampling are unwanted or not available.
ISSN:0932-0067
1432-0711
DOI:10.1007/s00404-014-3523-y