Efficacy of a prehospital self-expanding polyurethane foam for noncompressible hemorrhage under extreme operational conditions

Noncompressible abdominal hemorrhage is a significant cause of battlefield and civilian mortality. We developed a self-expanding polyurethane foam intended to provide temporary hemorrhage control and enable evacuation to a definitive surgical capability, for casualties who would otherwise die. We hy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of trauma and acute care surgery 2015-02, Vol.78 (2), p.324-329
Hauptverfasser: Rago, Adam P, Larentzakis, Andreas, Marini, John, Picard, Abby, Duggan, Michael J, Busold, Rany, Helmick, Marc, Zugates, Greg, Beagle, John, Sharma, Upma, King, David R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Noncompressible abdominal hemorrhage is a significant cause of battlefield and civilian mortality. We developed a self-expanding polyurethane foam intended to provide temporary hemorrhage control and enable evacuation to a definitive surgical capability, for casualties who would otherwise die. We hypothesized that foam treatment would be efficacious over a wide range of out-of-hospital operational conditions. The foam was tested in an established lethal, closed-cavity hepatoportal injury model in four groups as follows. Group 1 involved baseline conditions, wherein foam was deployed from a pneumatically driven, first-generation delivery device at room temperature (n = 6). Group 2 involved foam deployment from a field-relevant, handheld delivery prototype (n = 12). Group 3 involved foam components that were conditioned to simulate 1-year shelf-life (n = 6). Group 4 involved foam that was conditioned to a range of temperatures (10 °C and 50 °C; n = 6 per group). In all studies, survival was monitored for up to 180 minutes and compared with an ongoing and accumulating control group with no intervention (n = 14). In Group 1 with a first-generation delivery system, foam treatment resulted in a significant survival advantage relative to the control group (p < 0.001), confirming previous results. In Group 2 with a handheld delivery system, survival was also improved, 83% at 3 hours, compared with 7% in the control group (p < 0.001). In Group 3, survival was 83% at 3 hours (p = 0.002). In Group 4 at temperature extremes, 3-hour survival was 83% (p = 0.002) and 67% (p = 0.014) in the low- and high-temperature groups, respectively. Temperature extremes did not result in hypothermia, hyperthermia, or thermal injury. In all studies, the bleeding rate in foam groups was significantly lower than in the control group (p < 0.05). Under a range of military operational conditions, foam treatment resulted in a survival advantage relative to the control group. This supports the feasibility of foam treatment as a prehospital hemostatic bridge to surgery for severely bleeding causalities.
ISSN:2163-0755
2163-0763
DOI:10.1097/TA.0000000000000507