Pulmonary Valve Replacement: Twenty-Six Years of Experience With Mechanical Valvar Prostheses

Background Although the thromboembolic risk after pulmonary valve replacement (PVR) with mechanical valves is presumed to be high, recent studies suggest promising short-term and mid-term results. However, large studies reporting long-term mortality and valve-related complications are missing. Metho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2015-03, Vol.99 (3), p.905-910
Hauptverfasser: Freling, Hendrik G., MD, PhD, van Slooten, Ymkje J., MD, PhD, van Melle, Joost P., MD, PhD, Ebels, Tjark, MD, PhD, Hoendermis, Elke S., MD, PhD, Berger, Rolf M.F., MD, PhD, Hillege, Hans L., MD, PhD, Waterbolk, Tjalling W., MD, van Veldhuisen, Dirk J., MD, PhD, Willems, Tineke P., MD, PhD, Pieper, Petronella G., MD, PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Although the thromboembolic risk after pulmonary valve replacement (PVR) with mechanical valves is presumed to be high, recent studies suggest promising short-term and mid-term results. However, large studies reporting long-term mortality and valve-related complications are missing. Methods We describe valve-related complications in 66 patients with a mechanical pulmonary valvar prosthesis implanted between 1987 and 2013. Results Mean follow-up duration was 5.9 ± 4.8 years (median 4.9). Mean age at time of implantation was 35 ± 13 years. The most frequent underlying cardiac diagnosis was tetralogy of Fallot (77%). Valvar thrombosis or pannus was reported in 7 patients (10%) of which 4 in the setting of inadequate anticoagulation or pregnancy. Redo PVR was performed in 6 patients. Freedom from redo PVR in survivors after 5 and 10 years was 96% and 89%, respectively. Survival after 5 and 10 years was 91% and 81%, respectively. Main cause of death was end-stage heart failure. Conclusions Success of PVR using mechanical valvar prostheses over 26 years was limited because of valvar thrombosis (often in the setting of pregnancy or incompliance with anticoagulation therapy) or pannus. Performance of mechanical prostheses in the pulmonary position may improve when valvar thrombosis is prevented by patient selection, avoiding mechanical valves in patients at increased risk of valvar thrombosis, and by strict compliance to anticoagulation therapy.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2014.10.034