Research on Control Strategy of Hydro-Viscous Driven Fan Cooling System
The paper proposes a cascade control strategy of speed feedback in inner loop and temperature feedback in outer ring for hydro-viscous driven fan cooling system, and compares the simulation of PID and fuzzy PID. The simulation result shows that the double-loop control system while the response time...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2014-12, Vol.722 (Mechanical Engineering, Manufacturing and Automation Technologies), p.182-189 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The paper proposes a cascade control strategy of speed feedback in inner loop and temperature feedback in outer ring for hydro-viscous driven fan cooling system, and compares the simulation of PID and fuzzy PID. The simulation result shows that the double-loop control system while the response time longer, but much smaller overshoot, can achieve a good feedback to adjust the fan speed and temperature and realize stepless speed regulation of hydro-viscous driven fan cooling system under the premise of stability for fan speed and system temperature. |
---|---|
ISSN: | 1660-9336 1662-7482 1662-7482 |
DOI: | 10.4028/www.scientific.net/AMM.722.182 |