Iodine-131 monitoring in sewage plant outflow
Three different hospital sites (Oxford, Sutton and Guildford) have performed sampling of their local sewage plant outflow to determine levels of radioactivity resulting from iodine-131 patients undergoing radionuclide therapies. It was found that a maximum of 20% of activity discharged from the hosp...
Gespeichert in:
Veröffentlicht in: | Journal of radiological protection 2014-03, Vol.34 (1), p.1-14 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Three different hospital sites (Oxford, Sutton and Guildford) have performed sampling of their local sewage plant outflow to determine levels of radioactivity resulting from iodine-131 patients undergoing radionuclide therapies. It was found that a maximum of 20% of activity discharged from the hospitals was present in the sewage plant final effluent channel. This is significantly below the level predicted by mathematical models in current use. The results further show that abatement systems to reduce public exposure are unlikely to be warranted at hospital sites. |
---|---|
ISSN: | 0952-4746 1361-6498 |
DOI: | 10.1088/0952-4746/34/1/1 |