NO sub(2) measurement artifacts in the presence of soot
Nitrogen dioxide is a regulated pollutant, which is measured routinely. Since it can be formed during combustion processes, it is often measured in the presence of soot. This study investigates the possible artifact formation due to the interaction of soot and NO sub(2) in the sampling lines and ins...
Gespeichert in:
Veröffentlicht in: | Analytical and bioanalytical chemistry 2014-01, Vol.406 (2), p.447-453 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Nitrogen dioxide is a regulated pollutant, which is measured routinely. Since it can be formed during combustion processes, it is often measured in the presence of soot. This study investigates the possible artifact formation due to the interaction of soot and NO sub(2) in the sampling lines and instrument prefilters. The transfer of varying NO sub(2) concentrations through filters and tubes coated with different kinds of soot was investigated by using a dedicated photoacoustic soot and NO sub(2) analyzer (TwinPAS). The effects of flow rate, temperature, relative humidity, tubing respectively filter material, soot reactivity, and passivation on the NO sub(2) measurement artifacts have been investigated. We found significant lags (up to 2 min) of the NO sub(2) transfer as well as total NO sub(2) losses of up 10 %. |
---|---|
ISSN: | 1618-2642 1618-2650 |
DOI: | 10.1007/s00216-013-7495-8 |