Measuring the Curie temperature

Curie point temperatures (TC) of natural and synthetic magnetic materials are commonly determined in rock magnetism by several measurement methods that can be mutually incompatible and may lead to inconsistent results. Here the common evaluation routines for high‐temperature magnetization and magnet...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Geochemistry, geophysics, geosystems : G3 geophysics, geosystems : G3, 2013-04, Vol.14 (4), p.947-961
Hauptverfasser: Fabian, K., Shcherbakov, V. P., McEnroe, S. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Curie point temperatures (TC) of natural and synthetic magnetic materials are commonly determined in rock magnetism by several measurement methods that can be mutually incompatible and may lead to inconsistent results. Here the common evaluation routines for high‐temperature magnetization and magnetic initial susceptibility curves are analyzed and revised based on Landau's theory of second‐order phase transitions. It is confirmed that in high‐field magnetization curves TC corresponds to the inflection point, below the temperature of maximum curvature or the double‐tangent intersection point. At least four different physical processes contribute to the initial magnetic susceptibility near the ordering temperature. They include variation of saturation magnetization, superparamagnetic behavior, magnetization rotation, and magnetic domain wall motion. Because each of these processes may influence the apparent position of TC, initial susceptibility and high‐field curves can yield deviating estimates of TC. A new procedure is proposed to efficiently determine the temperature variation of several magnetic parameters on a vibrating‐sample magnetometer, by repeatedly measuring quarter‐hysteresis loops during a single heating cycle. This procedure takes measurements during the inevitable waiting time necessary for thermal equilibration of the sample, whereby it is not slower than the commonly performed measurements on a Curie balance. However, it returns saturation magnetization, saturation remanence, high‐field and low‐field slopes, and other parameters as a function of temperature, which provide independent information about TC and other sample properties. Key PointsTheory of Curie measurementsNew method for Curie point determinationComparability of Curie point measurements
ISSN:1525-2027
1525-2027
DOI:10.1029/2012GC004440