Impact of drug formulation and free platinum/cisplatin ratio on hypersensitivity reactions to cisplatin: formulation matters
Summary What is known and objective Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare t...
Gespeichert in:
Veröffentlicht in: | Journal of clinical pharmacy and therapeutics 2015-02, Vol.40 (1), p.41-47 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Summary
What is known and objective
Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare two different brands of cisplatin in relation to type I hypersensitivity reactions.
Methods
Brand A was used in a tertiary care teaching hospital until 2012, and use of brand B started from January 2013, when the first hypersensitivity cases were observed. Patients were categorized based on symptom. Cisplatin of both brands was analysed by high‐performance liquid chromatography (HPLC) and high‐resolution electrospray ionization mass spectrometry (ESI‐(+)‐MS) and characterized according to US Pharmacopeia.
Results and discussion
There were no cases of hypersensitivity associated with the use of cisplatin brand A, whereas four of 127 outpatients that used cisplatin brand B were affected. The two brands were in accordance with the US Pharmacopeia parameters, and there was no significant difference in the total platinum levels between the two brands when analysed by HPLC. However, high‐resolution ESI‐(+)‐MS analyses show that brand B contains approximately 2·7 times more hydrolysed cisplatin than brand A.
What is new and conclusion
The increase in the hydrolysed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. We present the first study of the quality of drugs by high‐resolution ESI‐(+)‐MS. Drug regulatory agencies and manufacturers should consider including measurement of hydrolysed cisplatin as a quality criterion for cisplatin formulations.
Some cases of hypersensitivity that appeared to be associated with the brand of cisplatin used were observed. Increases in the hydrolyzed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. |
---|---|
ISSN: | 0269-4727 1365-2710 |
DOI: | 10.1111/jcpt.12220 |