Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws

Highlights • Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our countr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of radiology 2015-03, Vol.84 (3), p.450-457
Hauptverfasser: Zou, Yue-fen, Chu, Bin, Wang, Chuan-bing, Hu, Zhi-yi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 457
container_issue 3
container_start_page 450
container_title European journal of radiology
container_volume 84
creator Zou, Yue-fen
Chu, Bin
Wang, Chuan-bing
Hu, Zhi-yi
description Highlights • Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our country. • In this study, it was verified that both titanium alloy and stainless steel materials (plates and screws) cause a weak force and low MRI-related heating at a 1.5-T or less, which do not pose an additional hazard or risk to patients. In addition, we also had explored the influence of different sequences and parameters on size of metallic artifacts to obtain optimized pulse sequences with appropriate parameters for reducing artifacts, which would be convenient and useful in clinical work.
doi_str_mv 10.1016/j.ejrad.2014.12.001
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1652461474</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0720048X14005634</els_id><sourcerecordid>1652461474</sourcerecordid><originalsourceid>FETCH-LOGICAL-c484t-8e2ae83aa0168927a68b3f93e235ff6ae885738582594e870985b53f1d6c47783</originalsourceid><addsrcrecordid>eNqFkVtrFTEUhYMo9lj9BYLk0ZcZc51kBAUp9QIVxQv4FnIyOzTjzOQ0yVT67830VB988SmBrJW917cQekpJSwntXowtjMkOLSNUtJS1hNB7aEe1Yo1STN1HO6IYaYjQP07Qo5xHQogUPXuITpiUQkgpd8ifX9tptSXEBUePP37BIecVMvYx4XIJeLIFcsG52GWwacD7VC9508ZULuMBhuDwDMVOOMyHyS4lv8Sfb124KnF2CX7lx-iBt1OGJ3fnKfr-9vzb2fvm4tO7D2dvLhontCiNBmZBc2trPt0zZTu9577nwLj0vqtvWiqupWayF6AV6bXcS-7p0DmhlOan6Pnx30OKVzVGMXPIDqa6F8Q1G9pJJjoqlKhSfpS6FHNO4M0hhdmmG0OJ2QCb0dwCNhtgQ5mpgKvr2d2AdT_D8Nfzh2gVvDoKoMa8DpBMdgEWVzklcMUMMfxnwOt__G4KS3B2-gk3kMe4pqUSNNTkajBft463iqmo7XZc8N-10KGm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1652461474</pqid></control><display><type>article</type><title>Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Zou, Yue-fen ; Chu, Bin ; Wang, Chuan-bing ; Hu, Zhi-yi</creator><creatorcontrib>Zou, Yue-fen ; Chu, Bin ; Wang, Chuan-bing ; Hu, Zhi-yi</creatorcontrib><description>Highlights • Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our country. • In this study, it was verified that both titanium alloy and stainless steel materials (plates and screws) cause a weak force and low MRI-related heating at a 1.5-T or less, which do not pose an additional hazard or risk to patients. In addition, we also had explored the influence of different sequences and parameters on size of metallic artifacts to obtain optimized pulse sequences with appropriate parameters for reducing artifacts, which would be convenient and useful in clinical work.</description><identifier>ISSN: 0720-048X</identifier><identifier>EISSN: 1872-7727</identifier><identifier>DOI: 10.1016/j.ejrad.2014.12.001</identifier><identifier>PMID: 25544555</identifier><language>eng</language><publisher>Ireland: Elsevier B.V</publisher><subject>Aged ; Alloys ; Androsterone - analogs &amp; derivatives ; Bone Screws ; Double-Blind Method ; Equipment Safety ; Female ; Humans ; Magnetic resonance imaging ; Magnetic Resonance Imaging - methods ; Male ; Metals ; Middle Aged ; Orthopedic implant ; Phantoms, Imaging ; Prostheses and Implants ; Radiology ; Safety ; Stainless steel ; Titanium ; Titanium alloy</subject><ispartof>European journal of radiology, 2015-03, Vol.84 (3), p.450-457</ispartof><rights>Elsevier Ireland Ltd</rights><rights>2014 Elsevier Ireland Ltd</rights><rights>Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c484t-8e2ae83aa0168927a68b3f93e235ff6ae885738582594e870985b53f1d6c47783</citedby><cites>FETCH-LOGICAL-c484t-8e2ae83aa0168927a68b3f93e235ff6ae885738582594e870985b53f1d6c47783</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.ejrad.2014.12.001$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25544555$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zou, Yue-fen</creatorcontrib><creatorcontrib>Chu, Bin</creatorcontrib><creatorcontrib>Wang, Chuan-bing</creatorcontrib><creatorcontrib>Hu, Zhi-yi</creatorcontrib><title>Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws</title><title>European journal of radiology</title><addtitle>Eur J Radiol</addtitle><description>Highlights • Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our country. • In this study, it was verified that both titanium alloy and stainless steel materials (plates and screws) cause a weak force and low MRI-related heating at a 1.5-T or less, which do not pose an additional hazard or risk to patients. In addition, we also had explored the influence of different sequences and parameters on size of metallic artifacts to obtain optimized pulse sequences with appropriate parameters for reducing artifacts, which would be convenient and useful in clinical work.</description><subject>Aged</subject><subject>Alloys</subject><subject>Androsterone - analogs &amp; derivatives</subject><subject>Bone Screws</subject><subject>Double-Blind Method</subject><subject>Equipment Safety</subject><subject>Female</subject><subject>Humans</subject><subject>Magnetic resonance imaging</subject><subject>Magnetic Resonance Imaging - methods</subject><subject>Male</subject><subject>Metals</subject><subject>Middle Aged</subject><subject>Orthopedic implant</subject><subject>Phantoms, Imaging</subject><subject>Prostheses and Implants</subject><subject>Radiology</subject><subject>Safety</subject><subject>Stainless steel</subject><subject>Titanium</subject><subject>Titanium alloy</subject><issn>0720-048X</issn><issn>1872-7727</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkVtrFTEUhYMo9lj9BYLk0ZcZc51kBAUp9QIVxQv4FnIyOzTjzOQ0yVT67830VB988SmBrJW917cQekpJSwntXowtjMkOLSNUtJS1hNB7aEe1Yo1STN1HO6IYaYjQP07Qo5xHQogUPXuITpiUQkgpd8ifX9tptSXEBUePP37BIecVMvYx4XIJeLIFcsG52GWwacD7VC9508ZULuMBhuDwDMVOOMyHyS4lv8Sfb124KnF2CX7lx-iBt1OGJ3fnKfr-9vzb2fvm4tO7D2dvLhontCiNBmZBc2trPt0zZTu9577nwLj0vqtvWiqupWayF6AV6bXcS-7p0DmhlOan6Pnx30OKVzVGMXPIDqa6F8Q1G9pJJjoqlKhSfpS6FHNO4M0hhdmmG0OJ2QCb0dwCNhtgQ5mpgKvr2d2AdT_D8Nfzh2gVvDoKoMa8DpBMdgEWVzklcMUMMfxnwOt__G4KS3B2-gk3kMe4pqUSNNTkajBft463iqmo7XZc8N-10KGm</recordid><startdate>20150301</startdate><enddate>20150301</enddate><creator>Zou, Yue-fen</creator><creator>Chu, Bin</creator><creator>Wang, Chuan-bing</creator><creator>Hu, Zhi-yi</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150301</creationdate><title>Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws</title><author>Zou, Yue-fen ; Chu, Bin ; Wang, Chuan-bing ; Hu, Zhi-yi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c484t-8e2ae83aa0168927a68b3f93e235ff6ae885738582594e870985b53f1d6c47783</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Aged</topic><topic>Alloys</topic><topic>Androsterone - analogs &amp; derivatives</topic><topic>Bone Screws</topic><topic>Double-Blind Method</topic><topic>Equipment Safety</topic><topic>Female</topic><topic>Humans</topic><topic>Magnetic resonance imaging</topic><topic>Magnetic Resonance Imaging - methods</topic><topic>Male</topic><topic>Metals</topic><topic>Middle Aged</topic><topic>Orthopedic implant</topic><topic>Phantoms, Imaging</topic><topic>Prostheses and Implants</topic><topic>Radiology</topic><topic>Safety</topic><topic>Stainless steel</topic><topic>Titanium</topic><topic>Titanium alloy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zou, Yue-fen</creatorcontrib><creatorcontrib>Chu, Bin</creatorcontrib><creatorcontrib>Wang, Chuan-bing</creatorcontrib><creatorcontrib>Hu, Zhi-yi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European journal of radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zou, Yue-fen</au><au>Chu, Bin</au><au>Wang, Chuan-bing</au><au>Hu, Zhi-yi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws</atitle><jtitle>European journal of radiology</jtitle><addtitle>Eur J Radiol</addtitle><date>2015-03-01</date><risdate>2015</risdate><volume>84</volume><issue>3</issue><spage>450</spage><epage>457</epage><pages>450-457</pages><issn>0720-048X</issn><eissn>1872-7727</eissn><abstract>Highlights • Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our country. • In this study, it was verified that both titanium alloy and stainless steel materials (plates and screws) cause a weak force and low MRI-related heating at a 1.5-T or less, which do not pose an additional hazard or risk to patients. In addition, we also had explored the influence of different sequences and parameters on size of metallic artifacts to obtain optimized pulse sequences with appropriate parameters for reducing artifacts, which would be convenient and useful in clinical work.</abstract><cop>Ireland</cop><pub>Elsevier B.V</pub><pmid>25544555</pmid><doi>10.1016/j.ejrad.2014.12.001</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0720-048X
ispartof European journal of radiology, 2015-03, Vol.84 (3), p.450-457
issn 0720-048X
1872-7727
language eng
recordid cdi_proquest_miscellaneous_1652461474
source MEDLINE; Elsevier ScienceDirect Journals
subjects Aged
Alloys
Androsterone - analogs & derivatives
Bone Screws
Double-Blind Method
Equipment Safety
Female
Humans
Magnetic resonance imaging
Magnetic Resonance Imaging - methods
Male
Metals
Middle Aged
Orthopedic implant
Phantoms, Imaging
Prostheses and Implants
Radiology
Safety
Stainless steel
Titanium
Titanium alloy
title Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T17%3A44%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20MR%20issues%20for%20the%20latest%20standard%20brands%20of%20orthopedic%20metal%20implants:%20Plates%20and%20screws&rft.jtitle=European%20journal%20of%20radiology&rft.au=Zou,%20Yue-fen&rft.date=2015-03-01&rft.volume=84&rft.issue=3&rft.spage=450&rft.epage=457&rft.pages=450-457&rft.issn=0720-048X&rft.eissn=1872-7727&rft_id=info:doi/10.1016/j.ejrad.2014.12.001&rft_dat=%3Cproquest_cross%3E1652461474%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1652461474&rft_id=info:pmid/25544555&rft_els_id=S0720048X14005634&rfr_iscdi=true