Analysis of a New All-Inside Versus Inside-Out Technique for Repairing Radial Meniscal Tears

Purpose The purpose of this study was to compare gap formation, strength, and stiffness of repaired radial tears of the meniscus treated using a new all-inside technique versus a traditional inside-out suture technique. Methods Radial tears were created in 36 fresh-frozen porcine menisci. Repairs we...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arthroscopy 2015-02, Vol.31 (2), p.293-298
Hauptverfasser: Beamer, Brandon S., M.D, Masoudi, Aidin, M.D, Walley, Kempland C., B.Sc, Harlow, Ethan R., B.Sc, Manoukian, Ohan S, Hertz, Ben, M.Sc, Haeussler, Claudia, Olson, Jeffrey J., B.Sc, Deangelis, Joseph P., M.D, Nazarian, Ara, Ph.D, Ramappa, Arun J., M.D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose The purpose of this study was to compare gap formation, strength, and stiffness of repaired radial tears of the meniscus treated using a new all-inside technique versus a traditional inside-out suture technique. Methods Radial tears were created in 36 fresh-frozen porcine menisci. Repairs were performed using a novel all-inside suture-based meniscal repair device or an inside-out technique. The repairs were tested for cyclic loading and load to failure. The displacement, response to cyclic loading (100, 300, and 500 cycles), and mode of failure were recorded, and the construct's stiffness was calculated. Results The all-inside repairs using the novel device resulted in a significantly lower displacement (gap formation) after 100, 300, and 500 cycles ( P  = .002, P  = .001, and P  = .001, respectively). The ultimate load to failure was significantly greater for the all-inside repairs (111.61 N v 95.01 N; P  = .03). The all-inside repairs showed greater stiffness (14.53 N/mm v 11.19 N/mm; P  = .02). The all-inside repairs failed most often by suture breakage (suture failure). The inside-out repairs failed most commonly when the suture pulled through the tissue (tissue failure) ( P < .001). Conclusions For repair of radial tears of the meniscus, the vertical suture configuration created by the all-inside technique resulted in lower displacement, higher load to failure, and greater stiffness compared with the horizontal inside-out technique. Clinical Relevance In a porcine specimen meniscus repair model, the biomechanical properties of a vertical all-inside technique were superior to that of a horizontal inside-out technique. Future studies of biomechanical and clinical outcomes in human meniscal repairs with this device are warranted to explore whether this repair method is valuable to clinical practice and patient outcomes.
ISSN:0749-8063
1526-3231
DOI:10.1016/j.arthro.2014.08.011