A new electrochemical sensor for the simultaneous determination of acetaminophen and codeine based on porous silicon/palladium nanostructure

A porous silicon/palladium nanostructure was prepared and used as a new electrode material for the simultaneous determination of acetaminophen (ACT) and codeine (COD). Palladium nanoparticles were assembled on porous silicon (PSi) microparticles by a simple redox reaction between the Pd precursor an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2015-03, Vol.134, p.745-753
Hauptverfasser: Ensafi, Ali A., Ahmadi, Najmeh, Rezaei, Behzad, Abarghoui, Mehdi Mokhtari
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A porous silicon/palladium nanostructure was prepared and used as a new electrode material for the simultaneous determination of acetaminophen (ACT) and codeine (COD). Palladium nanoparticles were assembled on porous silicon (PSi) microparticles by a simple redox reaction between the Pd precursor and PSi in an aqueous solution of hydrofluoric acid. This novel nanostructure was characterized by different spectroscopic and electrochemical techniques including scanning electron microscopy, X-ray diffraction, energy dispersive X-ray spectroscopy, fourier transform infrared spectroscopy and cyclic voltammetry. The high electrochemical activity, fast electron transfer rate, high surface area and good antifouling properties of this nanostructure enhanced the oxidation peak currents and reduced the peak potentials of ACT and COD at the surface of the proposed sensor. Simultaneous determination of ACT and COD was explored using differential pulse voltammetry. A linear range of 1.0–700.0µmolL−1 was achieved for ACT and COD with detection limits of 0.4 and 0.3µmolL−1, respectively. Finally, the proposed method was used for the determination of ACT and COD in blood serum, urine and pharmaceutical compounds. [Display omitted] •A new nanocomposite was synthesized by loading of Pd nanoparticles on porous silicon.•Pd/porous silicon nanocomposite was incorporated in carbon nanotube paste electrode.•The modified electrode was used for the determination of acetaminophen and codeine.•Voltammetry and amperometry were used for detection of acetaminophen and codeine.•Acetaminophen and codeine could be detect as low as 0.4 and 0.3µmolL−1, respectively.
ISSN:0039-9140
1873-3573