Acute coronary syndrome in two patients with mechanical valve prostheses

We report 2 similar cases of embolic myocardial infarction due to thrombus on a mechanical prosthesis despite anticoagulation therapy. In our first case, aspiration of the thrombus was performed successfully. Our second patient was given medical treatment with target international normalized ratio v...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Asian cardiovascular & thoracic annals 2015-02, Vol.23 (2), p.215-218
Hauptverfasser: Kaya, Dayimi, Alp, Alper, Elbi, Huseyin, Kupelioglu, Ali, Ozdogan, Oner
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report 2 similar cases of embolic myocardial infarction due to thrombus on a mechanical prosthesis despite anticoagulation therapy. In our first case, aspiration of the thrombus was performed successfully. Our second patient was given medical treatment with target international normalized ratio values between 3.5 and 4.0.
ISSN:0218-4923
1816-5370
DOI:10.1177/0218492313503573