Self-gated cardiac Cine MRI of the rat on a clinical 3 T MRI system

The ability to perform small animal functional cardiac imaging on clinical MRI scanners may be of particular value in cases in which the availability of a dedicated high field animal MRI scanner is limited. Here, we propose radial MR cardiac imaging in the rat on a whole‐body clinical 3 T scanner in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:NMR in biomedicine 2015-02, Vol.28 (2), p.162-167
Hauptverfasser: Krämer, Martin, Herrmann, Karl-Heinz, Biermann, Judith, Freiburger, Sebastian, Schwarzer, Michael, Reichenbach, Jürgen R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The ability to perform small animal functional cardiac imaging on clinical MRI scanners may be of particular value in cases in which the availability of a dedicated high field animal MRI scanner is limited. Here, we propose radial MR cardiac imaging in the rat on a whole‐body clinical 3 T scanner in combination with interspersed projection navigators for self‐gating without any additional external triggering requirements for electrocardiogram (ECG) and respiration. Single navigator readouts were interspersed using the same TR and a high navigator frequency of 54 Hz into a radial golden‐angle acquisition. The extracted navigator function was thresholded to exclude data for reconstruction from inhalation phases during the breathing cycle, enabling free breathing acquisition. To minimize flow artifacts in the dynamic cine images a center‐out half echo radial acquisition scheme with ramp sampling was used. Navigator functions were derived from the corresponding projection navigator data from which both respiration and cardiac cycles were extracted. Self‐gated cine acquisition resulted in high‐quality cardiac images which were free of major artifacts with spatial resolution of up to 0.21 × 0.21 × 1.00 mm3 and a contrast‐to‐noise ratio (CNR) of 21 ± 3 between the myocardium and left ventricle. Self‐gated golden ratio based radial acquisition successfully acquired cine images of the rat heart on a clinical MRI system without the need for dedicated animal ECG equipment. Copyright © 2014 John Wiley & Sons, Ltd. Using self‐gated golden ratio based radial acquisition cine images of the rat heart were acquired on a clinical MRI system without the need for dedicated animal ECG equipment. Shown are a navigator function obtained from the self‐gating data which was used for cardiac and respiratory triggering as well as images from a cardiac four chamber view.
ISSN:0952-3480
1099-1492
DOI:10.1002/nbm.3234