Inadequate Standard for Glove Puncture Resistance: Allows Production of Gloves with Limited Puncture Resistance

The National Fire Protection Association has developed standards for glove puncture resistance using a metal puncture probe. Biomechanical performance studies have demonstrated that glove puncture resistance to the probe is significantly greater than that of the hypodermic needle, suggesting that th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of emergency medicine 1998-05, Vol.16 (3), p.461-465
Hauptverfasser: Jackson, Elise M, Wenger, Mark D, Neal, Jeffrey G, Thacker, John G, Edlich, Richard F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The National Fire Protection Association has developed standards for glove puncture resistance using a metal puncture probe. Biomechanical performance studies have demonstrated that glove puncture resistance to the probe is significantly greater than that of the hypodermic needle, suggesting that these standards have no clinical relevance. These standards give a false sense of security to health care personnel and sanction the production and use of gloves that give inadequate protection. The result is potentially harmful for medical personnel.
ISSN:0736-4679
2352-5029
DOI:10.1016/S0736-4679(98)00017-1