Seismic performance of torsionally stiff and flexible multi-story concentrically steel braced buildings

SUMMARY It is expected that application of torsion provisions in typical seismic codes shows different levels of efficiency for torsionally stiff and flexible buildings. This paper studies difference in performances of a range of code designed torsionally stiff and flexible five‐story building model...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The structural design of tall and special buildings 2014-02, Vol.23 (2), p.146-160
Hauptverfasser: Haj Seiyed Taghia, S. A., Moghadam, A. S., Ghafory Ashtiany, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:SUMMARY It is expected that application of torsion provisions in typical seismic codes shows different levels of efficiency for torsionally stiff and flexible buildings. This paper studies difference in performances of a range of code designed torsionally stiff and flexible five‐story building models. The models are classified in eight configurations to cover common range of buildings designed with the seismic provisions of Iranian Standard 2800 as a typical seismic design code. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi‐directional design spectra compatible ground motions is investigated. These models cover a wide band of very torsionally stiff to very flexible buildings. Response parameters are element ductility demand and building story drift ratio. These criteria are appropriate indices for structural and nonstructural damages, respectively. The results indicate that the present linear static procedure of building codes such as the Iranian Standard 2800 is not generally adequate for structures with very low torsional stiffness. Copyright © 2012 John Wiley & Sons, Ltd.
ISSN:1541-7794
1541-7808
DOI:10.1002/tal.1031