Numerical investigation of fully developed laminar flow in irregular annular ducts: Triangular–circular combinations
•The friction factor – Reynolds number product in annular ducts is investigated.•The annular ducts are made up of equilateral triangular and circular ducts.•Irregular annuli outperformed the regular annuli currently used in industry.•The results lead to significant decrease in the required pumping e...
Gespeichert in:
Veröffentlicht in: | Energy conversion and management 2014-09, Vol.85, p.511-520 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The friction factor – Reynolds number product in annular ducts is investigated.•The annular ducts are made up of equilateral triangular and circular ducts.•Irregular annuli outperformed the regular annuli currently used in industry.•The results lead to significant decrease in the required pumping energy.
The aim of this study is to reduce the required pumping energy by obtaining accurately the friction factor – Reynolds number product (fRe) of the steady fully developed laminar flow in annular ducts. The study is focused on the annular region between equilateral triangular and circular ducts under all possible combinations. For this purpose, the governing equations are solved using high order finite element method. For regular annuli, it is found that higher values of area ratio lead to monotonic increase in (fRe) value, with (fRe)max=(24, 42.67,96) at the respective values of (Dh)=(0.5,0.75,1) regardless of the particular geometry. For irregular annuli, higher values of area ratio lead to an increase followed by a decrease in (fRe) value, with (fRe)max=(79.631,35.392,19.921) at the respective values of (Dh)=(0.5, 0.75, 1) for the (CT) case, and correspondingly (fRe)max=(91.02,40.45,22.85) for the (TC) case. On the other hand, it is found that (fRe) value inversely proportional with the hydraulic diameter (Dh). For all cases considered in this study, the largest (fRe) at the representative values (AR)=30% is found for the (CC) case with (fRe)max=95.43 whereas the smallest (fRe) is found for the (CT) case with (fRe)min=17.544. More importantly, irregular annuli outperformed the regular annuli and thus are recommended to replace the classical regular annuli currently used in double duct heat exchangers. This in turn will significantly decrease the pumping energy required in such applications in industry. |
---|---|
ISSN: | 0196-8904 1879-2227 |
DOI: | 10.1016/j.enconman.2014.06.001 |