The simultaneous detection of free and total prostate antigen in serum samples with high sensitivity and specificity by using the dual-channel surface plasmon resonance
Free/total prostate antigen (f/t-PSA) ratio in serum as a promising parameter has been used to improve the differentiation of benign and malignant prostate disease. In order to obtain the accurate and reliable f/t-PSA ratio, the simultaneous detection of f-PSA and t-PSA with high sensitivity and spe...
Gespeichert in:
Veröffentlicht in: | Biosensors & bioelectronics 2014-12, Vol.62, p.268-273 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Free/total prostate antigen (f/t-PSA) ratio in serum as a promising parameter has been used to improve the differentiation of benign and malignant prostate disease. In order to obtain the accurate and reliable f/t-PSA ratio, the simultaneous detection of f-PSA and t-PSA with high sensitivity and specificity is required. In this work, the dual-channel surface plasmon resonance (SPR) has been employed to meet the requirement. In one channel, t-PSA was directly measured with a linear range from 1.0 to 20.0ng/mL. In another channel, due to the low concentration of f-PSA in serum, the asynchronous competitive inhibition immunoassay with f-PSA@Au nanoparticles (AuNPs) was developed. As expected, the detection sensitivity of f-PSA was greatly enhanced, and a linear correlation with wider linear range from 0.010 to 0.40ng/mL was also achieved. On the other hand, a simple method was explored for significantly reducing the non-specific adsorption of co-existing proteins. On basis of this, the f/t-PSA ratios in serum samples from prostate cancer (PCa) or benign prostatic hyperplasia (BPH) patients were measured. And it was found that there was significant difference between the distributions of f/t-PSA ratio in BPH patients (16.44±1.77%) and those in PCa patients (24.53±4.97%). This present work provides an effective method for distinguishing PCa from BPH, which lays a potential foundation for the early diagnosis of PCa.
•The asynchronous competitive inhibition immunoassay for f-PSA was developed.•The detection sensitivity of f-PSA was greatly enhanced.•A simple method for eliminating the non-specific adsorption was explored.•The f/t-PSA ratios in serum samples of patients were obtained.•The ratio distributions between BPH and PCa show significant difference. |
---|---|
ISSN: | 0956-5663 1873-4235 |
DOI: | 10.1016/j.bios.2014.06.060 |