Comparison of new point-of-care troponin assay with high sensitivity troponin in diagnosing myocardial infarction

Abstract Objectives The aim of this study is to compare a new improved point of care cardiac troponin assay (new POC-cTnI) with 1. its predecessor (old POC-cTnI) and 2. a high sensitivity assay (hs-cTnI) for the diagnosis of acute myocardial infarction (AMI) and for major adverse cardiac events (MAC...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of cardiology 2014-11, Vol.177 (1), p.182-186
Hauptverfasser: Aldous, Sally, Mark Richards, A, George, Peter M, Cullen, Louise, Parsonage, William A, Flaws, Dylan, Florkowski, Christopher M, Troughton, Richard W, O'Sullivan, Jack W, Reid, Christopher M, Bannister, Laura, Than, Martin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Objectives The aim of this study is to compare a new improved point of care cardiac troponin assay (new POC-cTnI) with 1. its predecessor (old POC-cTnI) and 2. a high sensitivity assay (hs-cTnI) for the diagnosis of acute myocardial infarction (AMI) and for major adverse cardiac events (MACE) by 30 days. Methods This is a single centre observational study, set in Christchurch Hospital, New Zealand. Patients presenting to the emergency department with non-traumatic chest pain underwent blood sampling at 0 h and 2 h post presentation for analysis with the 3 cTnI assays for the outcome of AMI and for analysis using an accelerated diagnostic protocol (ADP-normal 2 h troponins, normal electrocardiograms and Thrombolysis In Myocardial Infarction (TIMI) score of 0 or ≤ 1) for 30 day MACE. Results Of 962 patients, 220 (22.9%) had AMI. Old POC-cTnI was least sensitive at 70.0% (65.4–73.9%) by 2 h ( p < 0.001). New POC-cTnI, sensitivity 93.6% (89.9–96.2%) had similar sensitivity to hs-cTnI, sensitivity 95.0% (91.5–97.3%) ( p = 0.508). There were 231 (24.0%) patients with 30 day MACE. When used as part of the ADP, all assays had 100% (98.0–100%) sensitivity using TIMI = 0. Sensitivities of new POC-cTnI ADP, 98.3% (95.4–99.4%), old POC-cTnI, 96.5% (93.2–98.4%) and hs-cTnI, 98.7% (96.0–99.7%) were similar ( p = 0.063–0.375) using TIMI ≤ 1. Conclusions A new POC-cTnI has improved sensitivity for AMI and MACE compared with its predecessor and comparable sensitivity to a high sensitivity assay. Now that sensitivities of the POC assay are improved, the new assay may be a useful alternative to central laboratory assays when rapid turn-around times are not possible.
ISSN:0167-5273
1874-1754
DOI:10.1016/j.ijcard.2014.09.026