Laboratory measurement of the permeability of selma chalk using an improved experimental technique
The permeabilities to water of 12 monolithic specimens of Selma chalk were determined in the laboratory using an apparatus featuring a micro-syringe pump which could be operated in either the controlled flow or controlled output pressure mode. Specimens 0.4 in. dia. x 2 in. long were diamond-core dr...
Gespeichert in:
Veröffentlicht in: | Hazardous waste & hazardous materials 1992, Vol.9 (4), p.331-343 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The permeabilities to water of 12 monolithic specimens of Selma chalk were determined in the laboratory using an apparatus featuring a micro-syringe pump which could be operated in either the controlled flow or controlled output pressure mode. Specimens 0.4 in. dia. x 2 in. long were diamond-core drilled from large blocks of Selma chalk obtained from a surface mine at Epes, AL. The mean pore radius of the chalk was found to be about 0.15 mu m, and the specific surface was 13.9 m super(2)/g. The specimens were mounted with epoxy in thick-walled cylindrical specimen holders under vacuum to assure that the epoxy penetrated a short distance into the specimens to prevent the possibility of liquid bypassing. Permeability values were found to range from 3.47 x 10 super(-8) to 1.68 x 10 super(-7) cm/s--within the range of values reported by other investigators. |
---|---|
ISSN: | 0882-5696 2331-4591 |
DOI: | 10.1089/hwm.1992.9.331 |