Chromatographic separation of neodymium isotopes by using chemical exchange process

The neodymium isotope effects were investigated in Nd–malate ligand exchange system using the highly porous cation exchange resin SQS-6. The temperature of the chromatographic columns was kept constant at 50 °C by temperature controlled water passed through the columns jackets. The separation coeffi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Chromatography A 2011-05, Vol.1218 (20), p.2923-2928
Hauptverfasser: Ismail, I.M., Ibrahim, M., Aly, H.F., Nomura, M., Fujii, Y.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The neodymium isotope effects were investigated in Nd–malate ligand exchange system using the highly porous cation exchange resin SQS-6. The temperature of the chromatographic columns was kept constant at 50 °C by temperature controlled water passed through the columns jackets. The separation coefficient of neodymium isotopes, ɛ’s, was calculated from the isotopic ratios precisely measured by means of an ICP mass spectrometer equipped with nine collectors as ion detectors. The separation coefficient, ɛ × 10 5, were calculated and found to be 1.4, 4.8, 5.4, 10.6, 16.8 and 20.2 for 143Nd, 144Nd, 145Nd, 146Nd, 148Nd and 150Nd, respectively.
ISSN:0021-9673
1873-3778
DOI:10.1016/j.chroma.2011.03.009