Electromembrane extraction of stimulating drugs from undiluted whole blood
For the first time, electromembrane extraction (EME) of six basic drugs of abuse from undiluted whole blood and post mortem blood in a totally stagnant system is reported. Cathinone, methamphetamine, 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxy-methamphet-amine (MDMA), ketamine and 2,5-d...
Gespeichert in:
Veröffentlicht in: | Journal of Chromatography A 2012-04, Vol.1232, p.27-36 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | For the first time, electromembrane extraction (EME) of six basic drugs of abuse from undiluted whole blood and post mortem blood in a totally stagnant system is reported. Cathinone, methamphetamine, 3,4-methylenedioxy-amphetamine (MDA), 3,4-methylenedioxy-methamphet-amine (MDMA), ketamine and 2,5-dimethoxy-4-iodoamphetamine (DOI) were extracted from the whole blood sample, through a supported liquid membrane (SLM) consisting of 1-ethyl-2-nitrobenzene (ENB) immobilized in the pores of a hollow fiber, and into an aqueous acceptor solution inside the lumen of the hollow fiber. The SLM acts as a barrier with efficient exclusion of all macromolecules and acidic substances in the sample. Due to the application of the electrical field, only the cationic compounds of interest are extracted efficiently across the membrane, thus providing extremely clean extracts for analysis with liquid chromatography–mass spectrometry, LC–MS. Recoveries in the range 10–30% were obtained from 80μl whole blood within 5min extraction time and an applied voltage of 15V across the SLM. The optimized technique was tested on real forensic whole blood samples taken from three forensic autopsy cases and on five forensic whole blood samples from living persons. The results were in agreement with the analysis using standard sample preparation methods (liquid–liquid extraction) performed on the same samples by Norwegian Institute of Public Health (NIPH), Division of Forensic Toxicology and Drug Abuse Research. Evaluation data were acceptable, with limit of detections (LODs) in the range 40–2610pg/mL, well below concentrations associated with drug abuse; linearites in the range between 10 and 250ng/mL with r2 values above 0.9939, and with repeatability (RSD) of 7–32%. |
---|---|
ISSN: | 0021-9673 1873-3778 |
DOI: | 10.1016/j.chroma.2011.08.058 |