Final report on APMP.M.F-K4.b key comparison for 2 MN force
This report gives the results of the APMP.M.F-K4.b key comparison in 2 MN force range. This regional key comparison was conducted under the Asia Pacific Metrology Program (APMP) to establish a link to the global CCM.F-K4.b key comparison. Seven institutes participated in this key comparison. The Nat...
Gespeichert in:
Veröffentlicht in: | Metrologia 2012-01, Vol.49, p.1-1 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This report gives the results of the APMP.M.F-K4.b key comparison in 2 MN force range. This regional key comparison was conducted under the Asia Pacific Metrology Program (APMP) to establish a link to the global CCM.F-K4.b key comparison. Seven institutes participated in this key comparison. The National Metrology Institute of Japan (NMIJ/AIST) served as the pilot institute. The Korea Research Institute of Standards and Science (KRISS) and the National Institute of Standards and Technology (NIST) together with NMIJ/AIST provided links to the CCM.F-K4.b key comparison. A pair of force transducers having 2 MN nominal capacities was circulated among the participants in a star formation. This regional key comparison revealed that all measurement results of the seven participants are coherent with the CCM.F-K4.b key comparison reference value within their uncertainties and that these participants are equivalent to each other. |
---|---|