Stabilization of Arsenite Wastes with Prior Oxidation

The stabilization of arsenite hazardous waste is more difficult than arsenate waste. Oxidation of arsenite was investigated as a pretreatment before stabilization of the resulting arsenate. The effectiveness of air oxidation was limited and depended on the amount of water present. Hydrogen peroxide...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of environmental engineering (New York, N.Y.) N.Y.), 2004-09, Vol.130 (9), p.1063-1066
Hauptverfasser: Fuessle, Robert W, Taylor, Max A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The stabilization of arsenite hazardous waste is more difficult than arsenate waste. Oxidation of arsenite was investigated as a pretreatment before stabilization of the resulting arsenate. The effectiveness of air oxidation was limited and depended on the amount of water present. Hydrogen peroxide oxidation was effective but limited by reactions with calcium hydroxide. After oxidation, the resulting arsenate waste was effectively stabilized using ferric sulfate.