Viscous flow through a sharp-edged orifice
A theoretical solution is proposed for the problem of flow through a thin orifice plate placed between chambers having large dimensions relative to the orifice diameter. Experimental results were obtained using molasses having a viscosity of the order of 1000 poise. These results confirmed the analy...
Gespeichert in:
Veröffentlicht in: | International journal of engineering science 1997-06, Vol.35 (8), p.725-729 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A theoretical solution is proposed for the problem of flow through a thin orifice plate placed between chambers having large dimensions relative to the orifice diameter. Experimental results were obtained using molasses having a viscosity of the order of 1000 poise. These results confirmed the analysis, but flow was found to be 5–10% less than the theoretical value. This is attributed to the finite size of the chambers of the apparatus and the finite thickness of the orifice plate. |
---|---|
ISSN: | 0020-7225 1879-2197 |
DOI: | 10.1016/S0020-7225(96)00123-1 |