Study on the Effect of Different Water Treatment Technology on Removing 2-MIB

To compare the removal efficiency of 2-MIB by traditional water treatment, prechlorination, O3-BAC, MIEX pre adsorption and UV/H2O2 advanced oxidation process, the pilot-test of drinking water odor control technology were studied in this paper. The results showed that the traditional water treatment...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Applied Mechanics and Materials 2014-07, Vol.587-589 (Sustainable Cities Development and Environment Protection IV), p.594-597
Hauptverfasser: Zhang, Dong, Wang, Zheng, Shen, Yu Qiong, Xia, Ping, Lu, Jing Rong, Ye, Hui
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To compare the removal efficiency of 2-MIB by traditional water treatment, prechlorination, O3-BAC, MIEX pre adsorption and UV/H2O2 advanced oxidation process, the pilot-test of drinking water odor control technology were studied in this paper. The results showed that the traditional water treatment process had poor effect on removing 2-MIB, with about 10% removal rate, while the O3-BAC process was the best at removing 2-MIB, whose removal rate reached over 90%. And the 2-MIB removal rate of UV/H2O2 process was about 55% and that of prechlorination process was about 20%. However, the MIEX pretreatment process had almost no effect on removing 2-MIB.
ISSN:1660-9336
1662-7482
1662-7482
DOI:10.4028/www.scientific.net/AMM.587-589.594