Study on the Effect of Different Water Treatment Technology on Removing 2-MIB
To compare the removal efficiency of 2-MIB by traditional water treatment, prechlorination, O3-BAC, MIEX pre adsorption and UV/H2O2 advanced oxidation process, the pilot-test of drinking water odor control technology were studied in this paper. The results showed that the traditional water treatment...
Gespeichert in:
Veröffentlicht in: | Applied Mechanics and Materials 2014-07, Vol.587-589 (Sustainable Cities Development and Environment Protection IV), p.594-597 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To compare the removal efficiency of 2-MIB by traditional water treatment, prechlorination, O3-BAC, MIEX pre adsorption and UV/H2O2 advanced oxidation process, the pilot-test of drinking water odor control technology were studied in this paper. The results showed that the traditional water treatment process had poor effect on removing 2-MIB, with about 10% removal rate, while the O3-BAC process was the best at removing 2-MIB, whose removal rate reached over 90%. And the 2-MIB removal rate of UV/H2O2 process was about 55% and that of prechlorination process was about 20%. However, the MIEX pretreatment process had almost no effect on removing 2-MIB. |
---|---|
ISSN: | 1660-9336 1662-7482 1662-7482 |
DOI: | 10.4028/www.scientific.net/AMM.587-589.594 |