Stented bovine jugular vein graft (Melody valve) for surgical mitral valve replacement in infants and children
Objective The options for mitral valve replacement in children with irreparable mitral valve disease have been limited to fixed-diameter prostheses that do not accommodate for somatic growth. We have modified an externally stented bovine jugular vein graft (Melody valve) for implantation in this coh...
Gespeichert in:
Veröffentlicht in: | The Journal of thoracic and cardiovascular surgery 2014-10, Vol.148 (4), p.1443-1449 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective The options for mitral valve replacement in children with irreparable mitral valve disease have been limited to fixed-diameter prostheses that do not accommodate for somatic growth. We have modified an externally stented bovine jugular vein graft (Melody valve) for implantation in this cohort. Because it is not a fixed-diameter prosthesis, we hypothesized that the valve can be expanded in the catheterization laboratory as the child grows. Methods The medical records of patients who had undergone Melody valve implantation in the mitral or left atrioventricular valve position from 2010 to 2013 were reviewed. Results Eleven patients had undergone Melody valve implantation at a median age of 7 months (range, 2-28). The techniques of valve modification and implantation included stent shortening, adding a pericardial sewing cuff, intraoperative balloon expansion, and fixation of the distal stent to the inferior left ventricle wall. The valve was competent, with a low gradient acutely postoperatively in all patients. One patient died, and one required permanent pacemaker implantation. One patient developed valve dysfunction and required explantation. Two patients without a pericardial sewing cuff developed paravalvular leaks. One patient who had not undergone distal stent fixation developed left ventricular outflow tract obstruction. Three patients who had undergone subsequent catheter-based balloon expansion of the valve have continued to demonstrate acceptable valvular function. Conclusions The Melody valve has demonstrated acceptable short-term function. Implantation techniques to prevent left ventricular outflow tract obstruction (suture fixation of the distal stent) and paravalvular leaks (the addition of a pericardial cuff) should be considered. The Melody valve can be percutaneously expanded as the child grows. |
---|---|
ISSN: | 0022-5223 1097-685X |
DOI: | 10.1016/j.jtcvs.2013.10.059 |