A randomized controlled trial studying efficacy and tolerance of a knee-ankle-foot orthosis used to prevent equinus in children with spastic cerebral palsy
Objective: To examine whether using a knee-ankle-foot orthosis helps maintain ankle-foot dorsiflexion range of motion over time. Design: A multicentre randomized controlled trial. Setting: Two hospitals and one rehabilitation centre in the Netherlands and the USA. Subjects: Children (4-16 years old)...
Gespeichert in:
Veröffentlicht in: | Clinical rehabilitation 2014-10, Vol.28 (10), p.1025-1038 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective:
To examine whether using a knee-ankle-foot orthosis helps maintain ankle-foot dorsiflexion range of motion over time.
Design:
A multicentre randomized controlled trial.
Setting:
Two hospitals and one rehabilitation centre in the Netherlands and the USA.
Subjects:
Children (4-16 years old) with spastic cerebral palsy who were able to walk.
Intervention:
Use of a knee-ankle-foot orthosis, equipped with an Ultraflex® ankle power unit, for at least 6 hours every other night for one year.
Main measures:
Primary outcome measure: ankle-foot dorsiflexion range of motion. Secondary outcome measures: ankle-foot and knee angle in gait and gross motor function. Wearing time was also measured. Measurements were taken at baseline and at 3, 6, 9 and 12 months.
Results:
28 children (experimental group: n=15, control group: n=13) participated in the study. 11 participants (experimental: n=4, control: n=7) did not complete all five measurements, as they needed additional treatment. No significant difference was found in the decrease of ankle-foot dorsiflexion range of motion between the experimental and control groups (difference: −1.05°, 95% confidence interval: −4.71° – 2.61°). In addition, secondary outcome measures did not show differences between groups. Despite good motivation, knee-ankle-foot orthosis wearing time was limited to a mean±SD of 3.2±1.9 hours per prescribed night due to discomfort.
Conclusions:
Knee-ankle-foot orthosis with dynamic ankle and fixed knee are poorly tolerated and are not beneficial in preventing a reduction in ankle-foot dorsiflexion range of motion in children with spastic cerebral palsy, at least with limited use. |
---|---|
ISSN: | 0269-2155 1477-0873 |
DOI: | 10.1177/0269215514542355 |