Digital quantification of air leak to identify the location of an alveolopleural fistula

This paper presents a case study of a patient developing a prolonged air leak after thoracic surgery for mesothelioma. The alveolopleural fistula was localized bronchoscopically by selective balloon occlusion of the right upper lobe segments and confirmation of decreased air leak on a digital thorac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of the American Thoracic Society 2014-09, Vol.11 (7), p.1152-1154
Hauptverfasser: Saettele, Timothy M, Jimenez, Carlos A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper presents a case study of a patient developing a prolonged air leak after thoracic surgery for mesothelioma. The alveolopleural fistula was localized bronchoscopically by selective balloon occlusion of the right upper lobe segments and confirmation of decreased air leak on a digital thoracic drainage system. Five endobronchial valves were placed in the right upper lobe with resolution of the air leak.