Aortopulmonary Fistula After Outflow Tract Stent in Repaired Truncus
We present a case of an iatrogenic aortopulmonary (AP) fistula in a 9-year-old patient with a history of repaired truncus arteriosus without the use of a right ventricle to pulmonary artery conduit and subsequent transcatheter placement of a right ventricular outflow tract (RVOT) stent. Redilation o...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 2014-09, Vol.98 (3), p.e55-e57 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We present a case of an iatrogenic aortopulmonary (AP) fistula in a 9-year-old patient with a history of repaired truncus arteriosus without the use of a right ventricle to pulmonary artery conduit and subsequent transcatheter placement of a right ventricular outflow tract (RVOT) stent. Redilation of the stent resulted in a defect in the aortic wall and the creation of an AP fistula with an associated hemodynamically significant left to right shunt. This case demonstrates a previously unreported adverse event of transcatheter RVOT reintervention after truncus arteriosus repair. |
---|---|