Optical imaging of visual cortical responses evoked by transcorneal electrical stimulation with different parameters

The use of phosphenes evoked by transcorneal electrical stimulation (TcES) has been proposed as a means of residual visual function evaluation and candidate selection before implantation of retinal prostheses. Compared to the subjective measures, measurement of neuronal activity in visual cortex can...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Investigative ophthalmology & visual science 2014-07, Vol.55 (8), p.5320-5331
Hauptverfasser: Ma, Zengguang, Cao, Pengjia, Sun, Pengcheng, Li, Liming, Lu, Yiliang, Yan, Yan, Chen, Yao, Chai, Xinyu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The use of phosphenes evoked by transcorneal electrical stimulation (TcES) has been proposed as a means of residual visual function evaluation and candidate selection before implantation of retinal prostheses. Compared to the subjective measures, measurement of neuronal activity in visual cortex can objectively and quantitatively explore their response properties to electrical stimulation. The purpose of this study was to investigate systematically the properties of cortical responses evoked by TcES. The visual cortical responses were recorded using a multiwavelength optical imaging of intrinsic signals (OIS) combining with electrophysiological recording by a multichannel electrode array. The effects of different parameters of TcES on cortical responses, including the changes of hemoglobin oxygenation and cerebral blood volume, were examined. We found consistent OIS activation regions in visual cortex after TcES, which also showed strong evoked field potentials according to electrophysiological results. The OIS response regions were located mainly in cortical areas representing peripheral visual field. The extent of activation areas and strength of intrinsic signals were increased with higher current intensities and longer pulse widths, and the largest responses were acquired in the frequency range 10 to 20 Hz. Use of TcES through the ERG-jet corneal electrode may preferentially activate peripheral retina. Revealing the hemodynamic changes in visual cortex occurred after electrical stimulation can contribute to comprehension of neurophysiological underpinnings underlying prosthetic vision. This study provided an objective foundation for optimizing parameters of TcES and would bring considerable benefits in the application of TcES for assessment and screening in patients.
ISSN:1552-5783
1552-5783
DOI:10.1167/iovs.14-14600