Radiation Exposure to Hand Surgeons’ Hands: A Practical Comparison of Large and Mini C-Arm Fluoroscopy
Purpose To determine and compare the radiation exposure to surgeons’ hands with large and mini C-arm fluoroscopy in a practical, clinically based model. Methods Two hand surgeons monitored radiation exposure to their hands with a ring dosimeter over a 14-month period using large and mini C-arm fluor...
Gespeichert in:
Veröffentlicht in: | The Journal of hand surgery (American ed.) 2014-09, Vol.39 (9), p.1805-1809 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose To determine and compare the radiation exposure to surgeons’ hands with large and mini C-arm fluoroscopy in a practical, clinically based model. Methods Two hand surgeons monitored radiation exposure to their hands with a ring dosimeter over a 14-month period using large and mini C-arm fluoroscopic units. One surgeon performed all cases with a large C-arm unit in a hospital setting, and the other performed all cases with mini C-arms in surgical centers. For each case, fluoroscopic time, the output displayed by the unit, radiation by time, and ring dosimeter absorption were recorded and analyzed. Results A total of 160 consecutive cases were reviewed with 71 cases and 89 cases in the large and mini C-arm groups, respectively. The median output displayed by the large C-arm was 0.7 mGy/case, and the median output displayed by the mini C-arm was 10.0 mGy/case. With output as a product of time, the median calculated values were 0.02 mGy/s for the large C-arm group and 0.28 mGy/s for the mini C-arm group. Cumulative ring dosimeter absorption to the surgeons’ hands was found to be 380 mrem for 71 cases in the large C-arm group versus 1,000 mrem for 89 cases in the mini C-arm group. Conclusions In our model, the use of the mini C-arm resulted in more than a 10-fold increase in the rate of output and approximately double the dosimeter absorption to the surgeon’s hand compared with the large C-arm. Although it has been shown that the mini C-arm produces less radiation scatter, in a practical model, it may not be a safer alternative with respect to the surgeon’s hands. Based on these findings, we recommend that surgeons be more aware of radiation exposure risk, know their C-arm unit’s specifications, and try to minimize radiation exposure. Type of study/level of evidence Prognostic II. |
---|---|
ISSN: | 0363-5023 1531-6564 |
DOI: | 10.1016/j.jhsa.2014.06.133 |