Development and evaluation of porcine atelocollagen vitrigel membrane with a spherical curve and transplantable artificial corneal endothelial grafts
To develop a collagen vitrigel (CV) optimized as a corneal endothelial cell (CEC) carrier and create an artificial corneal endothelial graft. We first developed a flat-shaped collagen vitrigel for regenerative medicine (CV-RM) using porcine atelocollagen and ultraviolet (UV) irradiation. The optimal...
Gespeichert in:
Veröffentlicht in: | Investigative ophthalmology & visual science 2014-07, Vol.55 (8), p.4975-4981 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To develop a collagen vitrigel (CV) optimized as a corneal endothelial cell (CEC) carrier and create an artificial corneal endothelial graft.
We first developed a flat-shaped collagen vitrigel for regenerative medicine (CV-RM) using porcine atelocollagen and ultraviolet (UV) irradiation. The optimal UV amount was determined by measuring the CV-RM transparency under various irradiating conditions. The collagen vitrigel for corneal endothelial regenerative treatment (CV-CERT), a transparent porcine atelocollagen with a curved shape, was made using spherically curved molds and UV irradiation. The membrane permeability of the CV-CERT was tested in vitro. The biocompatibility, transparency, and adhesiveness of the CV-CERT were evaluated in rabbit eyes. We also developed a culture technique for distributing human CECs on the curved CV-CERT.
The optimal amount of UV irradiation for CV-RM transparency was 2400 mJ/cm(2). Membrane permeability of CV-CERT at day 5 was higher than that of commercially available CV (P = 0.032). The CV-CERT was transparent and biocompatible in rabbit corneas for up to 4 months. The CV-CERT remained attached to the rabbit corneal posterior surface, whereas the flat-shaped CV-RM, differing only in shape from the CV-CERT, dislocated soon after surgery. Human CECs seeded on the CV-CERT using our technique were evenly distributed with a single layer structure and a mean cell density of 2650 ± 100 cells/mm(2).
We developed a transparent and biocompatible porcine-derived atelocollagen vitrigel membrane with a spherical curvature. A transplantable artificial endothelial graft was created by combining cultured human CECs and the CV-CERT. |
---|---|